Skip to main content

Enum Bh1750.MeasuringModes

The measuring mode of BH1750FVI

Assembly: Bh1750.dll​
View Source​
Declaration
public enum Bh1750.MeasuringModes : byte

Fields​

ContinuouslyHighResolutionMode​

Start measurement at 1lx resolution Measurement Time is typically 120ms

View Source​
Declaration
ContinuouslyHighResolutionMode = 16

ContinuouslyHighResolutionMode2​

Start measurement at 0.5lx resolution Measurement Time is typically 120ms

View Source​
Declaration
ContinuouslyHighResolutionMode2 = 17

ContinuouslyLowResolutionMode​

Start measurement at 4lx resolution Measurement Time is typically 16ms

View Source​
Declaration
ContinuouslyLowResolutionMode = 19

OneTimeHighResolutionMode​

Start measurement at 1lx resolution once Measurement Time is typically 120ms Automatically set to power-down mode after measurement

View Source​
Declaration
OneTimeHighResolutionMode = 32

OneTimeHighResolutionMode2​

Start measurement at 0.5lx resolution once Measurement Time is typically 120ms It is automatically set to Power Down mode after measurement

View Source​
Declaration
OneTimeHighResolutionMode2 = 33

OneTimeLowResolutionMode​

Start measurement at 4lx resolution once Measurement Time is typically 16ms It is automatically set to Power Down mode after measurement

View Source​
Declaration
OneTimeLowResolutionMode = 35